ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 2.8V to 14V, T
A
= T
J
= -40NC to +85NC, unless otherwise specified. Typical values are at V
ABP
= V
DBP
= V
CC
= 3.3V,
T
A
= +25NC.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Integral Nonlinearity
ADC
INL
1
LSB
Differential Nonlinearity
ADC
DNL
1
LSB
ADC Total Monitoring Cycle Time
t
CYCLE
Monitoring all 6 inputs, no MON_ fault
detected
24
30
F
s
ADC MON_ Ranges
ADC
RNG
MON_ range set to ‘00’
5.552
V
MON_ range set to ‘01’
2.776
MON_ range set to ‘10’
1.388
ADC LSB Step Size
ADC
LSB
MON_ range set to ‘00’
5.42
mV
MON_ range set to ‘01’
2.71
MON_ range set to ‘10’
1.35
ADC Input Leakage Current
1
F
A
ENABLE INPUT (EN)
EN Input-Voltage Threshold
V
TH_EN_R
EN voltage rising
1.24
V
V
TH_EN_F
EN voltage falling
1.195
1.215
1.235
EN Input Current
I
EN
-0.5
+0.5
F
A
EN Input-Voltage Range
0
3.6
V
OUTPUTS (RESET, GPIO_)
Output-Voltage Low
V
OL
I
SINK
= 2mA
0.4
V
I
SINK
= 10mA, GPIO_ only
0.7
V
CC
= 1.2V, I
SINK
= 100FA (RESET only)
0.3
Maximum Output Sink Current
Total current into RESET, GPIO_,
V
CC
= 3.3V
18
mA
Output-Voltage High (Push-Pull)
V
OH
I
SOURCE
=100FA
2.4
V
Output Leakage Current
(Open-Drain)
I
OUT_LKG
1
F
A
INPUTS (A0, GPIO_)
Input Logic-Low
V
IL
0.8
V
Input Logic-High
V
IH
20
V
WDI Pulse Width
t
WDI
100
ns
MR Pulse Width
t
MR
2
F
s
SMBus INTERFACE
Logic-Input Low Voltage
V
IL
Input voltage falling
0.8
V
Logic-Input High Voltage
V
IH
Input voltage rising
2.0
V
Input Leakage Current
V
CC
shorted to GND, V
MON_
= 0 or 6V
-1
+1
F
A
Output Sink Current
V
OL
I
SINK
= 3mA
0.4
V
Input Capacitance
C
IN
5
pF