MAX7356/MAX7357/MAX7358

1-to-8 I

2

C Bus Switches/Multiplexers with Bus

Lock-Up Detection, Isolation, and Notification

12

______________________________________________________________________________________

Available addresses depend on the hardware connec-
tions of pins A2, A1, and A0 as shown in Table 1.

The last bit following the slave address bit A0 on an I

2

C

command defines the operation to be performed. When
the last bit sets to logic 1, a read is selected while logic
0 selects a write operation.

Register Map (MAX7357/MAX7358)

The MAX7357 and MAX7358 have 7 registers (shown in
Table 2) that can be accessed through the I

2

C bus. The

MAX7357 powers up with all of these registers accessi-
ble. The initial register address counter is at 0x00. The
MAX7358 powers up in basic mode with only the switch
control register available. Writing to a MAX7358
changes only the contents of the switch control register.
By sending a unique I

2

C sequence to the MAX7358, all

7 registers become available.

Register Access Protocol (MAX7356)

Only the MAX7356 device address is required to gain
access to its registers. A typical I

2

C command to com-

municate with the MAX7356 starts with its device
address followed directly by data bytes.

A5

R/W

A6

A4

A3

A2

A1

A0

FIXED

PIN-SELECTABLE BITS

Figure 7. MAX7356/MAX7357/MAX7358 Slave Address

A2

CONNECTION

A1

CONNECTION

A0

CONNECTION

A6

A5

A4

A3

A2

A1

A0

GND

GND

GND

1

1

1

0

0

0

0

GND

GND

V

DD

1

1

1

0

0

0

1

GND

V

DD

GND

1

1

1

0

0

1

0

GND

V

DD

V

DD

1

1

1

0

0

1

1

V

DD

GND

GND

1

1

1

0

1

0

0

V

DD

GND

V

DD

1

1

1

0

1

0

1

V

DD

V

DD

GND

1

1

1

0

1

1

0

V

DD

V

DD

V

DD

1

1

1

0

1

1

1

Table 1. MAX7356/MAX7357/MAX7358 Switch Multiplexer Device Address

POR DEFAULT SETTING

REGISTER

NAME

B7 B6

B5 B4

B3

B2

B1 B0

ACCESS

Switch

Control

0

0

0

0

0

0

0

0

R/

W

Table 3. MAX7357 and MAX7358 Basic-
Mode Register Map

POR DEFAULT SETTING

REGISTER NAME

INTERNAL

ADDRESS

B7

B6

B5

B4

B3

B2

B1

B0

NEXT

ADDRESS

ACCESS

Switch Control

0x00

0

0

0

0

0

0

0

0

0x01

R/W

Configuration

0x01

0

0

0

0

0

0

0

1

0x02

R/W

Flush-Out Sequence

0x02

1

1

1

1

1

1

1

1

0x00 (W)

0x03 (R)

R/W

Lock-Up Indication

0x03

0

0

0

0

0

0

0

0

0x04

R

0x04

0

0

0

0

0

0

0

0

0x05

R

Traffic Prior to Lock-Up

0x05

0

0

0

0

0

0

0

0

0x06

R

Stuck High Fault

0x06

0

0

0

0

0

0

0

0

0x00

R

Table 2. MAX7357/MAX7358 Enhanced-Mode Register Map