beautypg.com

Rainbow Electronics W29EE512 User Manual

Page 11

background image

W29EE512

Publication Release Date: April 2000

- 11 - Revision A6

Read Cycle Timing Parameters

(V

CC

= 5.0V

±

10

%

, V

CC

= 5.0

±

5

%

for 70 nS, V

SS

= 0V, T

A

= 0 to 70

°

C)

PARAMETER

SYM. W29EE512-70 W29EE512-90 W29EE512-12 UNIT

MIN. MAX. MIN. MAX. MIN. MAX.

Read Cycle Time

T

RC

70

-

90

-

120

-

nS

Chip Enable Access Time

T

CE

-

70

-

90

-

120

nS

Address Access Time

T

AA

-

70

-

90

-

120

nS

Output Enable Access Time

T

OE

-

35

-

40

-

50

nS

CE High to High-Z Output

T

CHZ

-

25

-

25

-

30

nS

OE High to High-Z Output

T

OHZ

-

25

-

25

-

30

nS

Output Hold from Address Change

T

OH

0

-

0

-

0

-

nS

Byte/Page-write Cycle Timing Parameters

PARAMETER

SYMBOL

MIN.

TYP.

MAX.

UNIT

Write Cycle (Erase and Program)

T

WC

-

-

10

mS

Address Setup Time

T

AS

0

-

-

nS

Address Hold Time

T

AH

50

-

-

nS

WE and CE Setup Time

T

CS

0

-

-

nS

WE and CE Hold Time

T

CH

0

-

-

nS

OE High Setup Time

T

OES

0

-

-

nS

OE High Hold Time

T

OEH

0

-

-

nS

CE Pulse Width

T

CP

90

-

-

nS

WE Pulse Width

T

WP

90

-

-

nS

WE High Width

T

WPH

100

-

-

nS

Data Setup Time

T

DS

35

-

-

nS

Data Hold Time

T

DH

0

-

-

nS

Byte Load Cycle Time

T

BLC

-

-

200

µ

S

Notes: All AC timing signals observe the following guidelines for determining setup and hold times:

(1) High level signal's reference level is V

IH

.

(2) Low level signal's reference level is V

IL

.