This manual will explain how to replace the mechanical media (grit) valve on a wheel type blast
cleaning machine with the new MagnaValve automatic media regulator. The two most prominent
reasons for this type of upgrade are:

a) to eliminate maintenance required for the air cylinder that operates the mechanical valve
b) to provide an automatic alarm to alert the operator to replenish the shot/grit supply


The machine used for illustration in this manual is a RotoPeen system from Pangborn Corporation
modified to shot blast clean 20 foot lengths of round pipe. It is a single wheel, 20 horsepower, pass-
thru cabinet design as shown in Fig. 1 below.

The following text will describe each of the remaining photos in three sections, before, during and
after the installation of the MagnaValve. The entire project required less than one day for the con-
version.

Fig. 1

Note: To operate properly and prevent damage to the MagnaValve, always supply the full flow ca-
pacity of the valve. For example, a VLP will flow 1000lbs/min. While only 400lbs maximum is re-
quired for the application, the MagnaValve must be supplied the full 1000lbs to operate correctly. If
an amount less than 1000lbs is supplied, the shot travels through the valve at a high velocity, and
can damage the valve.