Options for 2 ring doors – Grain Systems Tanks PNEG-1093 User Manual
Page 56
6. Installation
56
PNEG-1093 2.66" Corrugation Unstiffened Bin
Options for 2 Ring Doors
Inner Door Auger Hood 12' (3.66 m) - 24' (7.32 m) Diameters Only
1. Remove bolts, lock washers and
nuts along each side of large
square opening on the inner
door panel.
2. Position auger shield as shown in
and bolt to underside
of top angle with bolt heads under
shield. Replace bolts, lock
washers and nuts through inner
door panel and auger shield.
3. Attach inner door panel to inner
bin door and outer door panel to
the outer bin door.
Figure 6X
Bin step
1. Attach the left and right sides to
the sides of the bin step using
four (4) 5/16" x 3/4" grade 5 hex
head bin bolts and nuts.
2. Center assembled step under
bin door and use it as a template
to field drill the holes in the
sidewall sheet on the ridges
of the corrugation.
Figure 6Y
CAUTION
Unloading grain through door opening may cause grain bin failure if not done
properly. Unloading directly through the door opening should be limited to grain bins
no larger than 24' (7.32 m) diameter and grain depths no greater than 18' (5.49 m).
Unloading from the door opening should be done only with use of an auger hood
with the auger inserted through the opening all the way to the center of the bin.