5. Foundation

PNEG-1093 2.66" Corrugation Unstiffened Bin

17

Placing the Reinforcement

1. Once the forms and trench have been prepared, begin the placement of reinforcement rods and

mesh at various levels in the foundation’s footing. (See the appropriate charts and drawings for the
bin to determine requirements and positions of the reinforcement

on Page 18-26.

) Reinforcement

rods should be properly lapped by wiring.

2. Next, place a minimum of 2" of compacted sand on the inside section of the foundation to provide a

good base for the concrete and protect against rodents.

3. The sand should then be covered with 4 mil polyethylene plastic which will act as a moisture barrier.

4. Two (2) layers of 6" x 6" wire mesh should then be added to the entire area of the foundation slab or

the entire foundation for monolithic systems to complete the preparation of the bin’s foundation.

Figure 5C Octagon Form

* All concrete to have a minimum compressive
strength of 3000 PSI at 28 days.

2" x 8" Forms

6" x 6" Wire mesh

Footing trench

Foundation line