Outside bin hold-down chart (2.66" corrugation), Foundation – Grain Systems Tanks PNEG-1093 User Manual
Page 21
5. Foundation
PNEG-1093 2.66" Corrugation Unstiffened Bin
21
Outside Bin Hold-Down Chart (2.66" Corrugation)
Outside bin hold-downs should be used on all non-stiffened bins/silos. When anchoring the bin, be sure
the vertical seams of the bin/silo align with the U-bolts or single anchor bolts in the foundation. Bin/silos
up to 36' diameter and 12 rings tall or shorter may be anchored using either the U-bolt/J-bolt combination
or the single anchor bolt. Bin/silos 42' and greater in diameter and all 13 rings or taller should be anchored
using the single anchor bolt. Bins/silos 13 rings and taller require double hold-downs. The sidewall must
be field drilled to attach the hold-down bracket located between the horizontal seams. For the case of
42' and larger bin/silo, no greater than 12 rings tall, double U-bolt/J-bolt combination anchors may be
used as an option to the single anchors bolt. Additional hold-downs are required with this option. Refer to
Page 53
for outside hold-down bracket details.
Single Anchor Bolt Chart
Bin Diameter
“B” Bolt Circle Radius
For 3-12 Rings
# of Anchors
“E” Chord Distance
12'
6' - 1-3/8"
4
8' - 7-3/4"
15'
7' - 7-1/4"
5
8' - 11-5/16"
18'
9' - 1-3/16"
6
9' - 1-3/16"
21'
10' - 7-1/16"
7
9' - 2-1/4"
24'
12'-1"
8
9' - 2-15/16"
27'
13' - 6-7/8"
9
9' - 3-7/16"
30'
15' - 0-13/16"
10
9' - 3-3/4"
33'
16' - 6-11/16"
11
9' - 3-15/16"
36'
18' - 0-9/16"
12
9' - 4-1/8"
42'
21' - 0-7/16"
14
9' - 4-3/8"
48'
24' - 0-1/4"
16
9' - 4-1/2"
60'
29' - 11-7/8"
20
9' - 4-9/16"
Double Hold-Down Anchors Required
for 13-15 Rings
# of Anchors
“F” Chord Distance
8
4' - 8-3/16"
10
4' - 8-3/8"
12
4' - 8-1/2"
14
4' - 8-9/16"
16
4' - 8-9/16"
18
4' - 8-9/16"
20
4' - 8-9/16"
22
4' - 8-9/16"
24
4' - 8-9/16"
28
4' - 8-1/2"
32
4' - 8-1/2"
40
4' - 8-1/2"