6. Installation

44

PNEG-1093 2.66" Corrugation Unstiffened Bin

Eave Adjustable Braces

The adjustable braces must be attached at this time. A larger diameter tube and two (2) smaller tubes are
used to make up one adjustable brace.

(See Figure 6J.)

Slip the smaller tubes inside the larger tubes and

attach one smaller tube to the top of the ladder extension rail. Adjust the other smaller tube so the bottom
of the flattened tube reaches the roof panel. Field drill four (4) 5/16" holes through both large and small
tubes and bolt together using 1/4" x 1-1/2" bolts and nuts. This will keep the adjustable braces from
slipping.

(See Figure 6K.)

Figure 6J

Figure 6K