Installation, Chapter 6 installation, Sidewall erection – Grain Systems Tanks PNEG-1093 User Manual
Page 28: Sidewall erection instructions, Overlapping panels
28
PNEG-1093 2.66" Corrugation Unstiffened Bin
6. Installation
Sidewall Erection
Sidewall Erection Instructions
Gauge Color Code
1. Before bolting the sidewall sheets together, check that you have the proper gauge steel for the first
ring. The higher gauge numbers denote the thinner materials. (For example, 20 gauge material is
thinner than 14 gauge.)
2. In erecting most grain bins, the thinnest material usually goes on top, therefore the first sidewall ring
you assemble will be the top ring of the bin.
3. Check the various gauges of the bin with the color code chart and begin building accordingly.
REMEMBER..... Assemble the top ring first.
Overlapping Panels
1. Once you have selected the proper gauge material, begin assembling all sidewall sheets in the
following manner: Standing on the inside of the bin, place the left panel to the inside with the right
panel to the outside.
Check to see that the sidewall sheet is “Right Side Up”.
Figure 6A
Gauge
Color Code
20
Red
19
Black/Yellow
18
Orange
17
Pink/Light Blue
16
Blue
15
Brown/Red
14
Green
13
Yellow/Blue
12
Black
11
Pink
10
Light Blue
9
Blue/Orange
8
Yellow
6
White
5
Fluorescent Green