beautypg.com

00 outside stiffened ladder placement – Grain Systems Bin Accessories PNEG-1096 User Manual

Page 56

background image

56

PNEG-1096 Ladder, Safety Cage, & Platforms

4.00 OUTSIDE STIFFENED

LADDER PLACEMENT

Ladder placement on the grain bin is very im-
portant at this time. Refer to the diagram at the
left and follow the correct dimensions as shown.
Ladder standoff must be located 8" below the
horizontal seam. Check your ladder to make
sure the ladder rung dimples are to the top sur-
face. Attach ladder to the standoffs using the
holes located 6 1/4" from the end of ladder sec-
tion. Use 5/16" x 3/4" bin bolts for these connec-
tions. Now all standoffs must be located in hori-
zontal seam holes (repeating every 44") until
reaching the first rest platform. Refer to the sec-
tion in these instructions that references the lo-
cation of intermediate rest platforms for further
hole locations.

REV. 4/19/01

Roof Sheet

Ladder Section
LDR-4002

Outside
Standoffs
LS-121

8"

8"

6.1/4"