PNEG-1096 Ladder, Safety Cage, & Platforms

2.66 OUTSIDE STIFFENED

Ladder Section
LDR-4002

Roof Sheet

6.1/4"

8"

8"

Outside Standoff
LS-121

FIELD DRILL
3/8" HOLES

FIELD DRILL
3/8" HOLES

56.1/4"

4"

18.3/4"

MANWAY SHEET

ROOF LADDER

LADDER PLACEMENT

Ladder placement on the grain bin is very im-
portant at this time. Refer to the diagram at the
left and follow the correct dimensions as shown.
Ladder standoff must be located 8" below the
horizontal seam. Check your ladder to make sure
the ladder rung dimples are to the top surface.
Attach ladder to the standoffs using the holes
located 6 1/4" from the end of ladder section.
Use 5/16" x 3/4" bin bolts for these connections.
Now all standoffs must be located in horizontal
seam holes (repeating every 32") until reaching
the first rest platform. Refer to the section in these
instructions that references the location of inter-
mediate rest platforms for further hole locations.