2 Technical Information
2.2
Technical data, VEGASON 71 - D
Power supply
Operating voltage
- Standard
U
nenn
= 24 V AC (16 … 42 V), 50/60 Hz
U
nenn
= 24 V DC (16 … 60 V)
- Option
U
nenn
= 230 V AC (90 … 250 V), 50/60 Hz
Power consumption at U
nenn
and max-load
12 VA, 5 W
Fuse for version
16 … 42 V AC or 16 … 60 V DC
2 A
90 … 250 V AC
500 mA
Measuring range
Min. distance
0.300 m
Max. distance
4.000 m (5.000 m)
Measuring data
Min. span
10 cm
Display in
m (0.000 … 5.000 distance)
Resolution in
mm
Scanning
3 mm
Measuring frequency
50 kHz
Measuring rate
0,4 sec.
Angle of reflection (at –3 dB)
8
°
Linearity error after empty and full adjustment
< 0,1 % of measuring range
Temperature error of the electronics
0,1 % / 10 k of measuring range
Central electronics
Inputs
1 (1 channel, for 1 sensor)
Outputs
see section "output"
Housing material
Polycarbonate
Electrical connection
max. 1,5 mm
2
Cable entry
1 x Pg 7, 1 x Pg 13,5 (up to max. 5 x Pg 13,5)
Protection
IP 65
Ambient temperature
-20
°
C … +60
°
C
Storage and transport temperature
-20
°
C … +80
°
C
Weight
approx. 1,9 kg
Output
Indication
LC-display
2, 4-digit each
Flow module
1 flow relay output
active, with status indication (LED)
- voltage impulse
24 V
- current impulse
20 mA
- pulse duration
200 ms
1 sampling relay output
floating spdt, with status indication (LED)
- contact material
AgCdO and Au plated
- min.
turn-on voltage
10 mV
switching current
10
µ
A
- max.
turn-on voltage
250 V AC, 60 V DC
switching current
2 A AC, 1 A DC
- max.
breaking capacity
125 VA, 60 W