VEGA VEGASON 71 - D User Manual
Page 16

VEGASON 71 - D
16
4.2
Mode range, general parameter adjustment (continuation)
Function
Mode-no.
Mode description
Parameter
Page
(bold = factory settings)
(level
0 - 58
Coordination
module)
- measuring result in m ........................................
1
- measuring result in % ........................................
2
2
2
2
2
0 - 59
not coordinated ......................................................
– – – –
P. 32
Switching command
0 - 60
- on ......................................................................
0.000
m …
5.000
m
0 - 61
- off ......................................................................
0.000
m …
5.000
m
0 - 62
…
64
not coordinated ......................................................
– – – –
Current
Characteristics
module
0 - 65
- end ....................................................................
20.00
20.00
20.00
20.00
20.00
…
00.00
P. 33
0 - 66
- begin .................................................................
00.00
…
04.00
04.00
04.00
04.00
04.00
…
20.00
0 - 67
…
81
not coordinated ......................................................
– – – –
Max.
0 - 82
Flow (max. 4 positions) ..........................................
0001
…
9999
…
1000
1000
1000
1000
1000
flow
0 - 83
Multiplier
(at level
- flow x 1 ..............................................................
0
0
0
0
0
100 %)
- flow x 10 ............................................................
1
- flow x 100 ..........................................................
2
P. 24
- flow x 1000 ........................................................
3
0 - 84
Time unit for above flow
- seconds .............................................................
1
11
11
- minutes ..............................................................
2
- hours .................................................................
3
Flow
module
Pulse value
0 - 85
Flow quantity / impulse ..........................................
0001
…
9999
…
1000
1000
1000
1000
1000
for flow
0 - 86
Multiplier
relay
- flow quantity / impulse x 1 .................................
0
0
0
0
0
P. 24
- flow quantity / impulse x 10 ...............................
1
- flow quantity / impulse x 100 .............................
2
- flow quantity / impulse x 1000 ...........................
3
Pulse value
0 - 87
Flow quantity / impulse ..........................................
0001
…
9999
…
1000
1000
1000
1000
1000
for samp-
0 - 88
Multiplier
ling relay
- flow quantity / impulse x 1 .................................
0
- flow quantity / impulse x 10 ...............................
1
11
11
- flow quantity / impulse x 100 .............................
2
P. 25
- flow quantity / impulse x 1000 ...........................
3
- flow quantity / impulse x 10000 .........................
4
- flow quantity / impulse x 100000 .......................
5
- flow quantity / impulse x 1000000 .....................
6
0 - 89
Time dependent controls in hours .........................
0
0
0
0
0
(off) …
100
0 - 90
Min. flow volume limit in % .....................................
0.0
0.0
0.0
0.0
0.0
…
100
P. 25
0 - 91
u.
92
not coordinated ......................................................
– – – –
4 Set-up
Relay
output 2
Current out-
put 1 + 2