2 operation – VEGA VEGASON 71 - D User Manual
Page 13
VEGASON 71 - D
13
3 Operating surface
1. Indication
of mea-
sured
values
2. Mode
range
3. Parameter
adjustment
3.2
Operation
VEGASON 71 - D has 3 modes which can be enquired with the MOD-button (scrolling)
-
indication of measured values
-
mode range
-
parameter adjustment.
After 60 mins. VEGASON 71 - D resets automatically to mode "Indication of measured values".
MOD
MOD
+
-
MOD
STO
+
-
5.000
0 00
0 99
48.94
0 - 00
– – – –
0
1. Indication of measured value
Flow in m
3
/h
Flow in %
Level in %
Distance in m
2. Mode range
Enquiry of the mode numbers in the MODEFIELD. The
parameters of the enquired mode numbers can be
checked or modified in mode 3.
3. Parameter adjustment
Programming of the parameters in the PARAMETER
FIELD. The parameter of the respectively enquired
mode can be modified and stored with the key STO.
Push the MOD-key if no modification is desired or if the
modified parameter should not be stored. In both cases
reset in mode 1.
In mode 99 the mode range of the general parameter adjustment can be quit and the optimization as well as the
linearization curve 4 … 6 can be enquired. Reset also in mode 99.
If after STO the actual mode range is enquired again within 60 mins., the last enquired mode number appears
automatically.
Cursor position
Figures raise
Figures lower
Cursor position
Figures raise
Figures lower