4 rectangular weir with throat, Calculation of the actual flow value (q), Selection of the actual flow (q) – VEGA VEGASON 71 - D User Manual
Page 29
VEGASON 71 - D
29
7 Output results
7.6.4 Rectangular weir with throat
With sharp weir edge and throat
Weir edge
K = 6290
Calculation of the actual flow value (Q)
The following formula can be used for calculation of the
actual flow for liquid levels < h
max
… > h
min
.
Q = B • K • h
1,5
Q in m
3
/h
B in m
h in m
Assumed values for a calculation example
B =
0,4 m
K =
6290
h =
0,13 m
Calculation example
Q =
0,4 • 6290 • 0,13
1,5
= 117,9 m
3
/h
Programming acc. to calculation example
Q
max
= 117,9 m
3
/h
- Mode
0 - 82
, flow = 0118
- Mode
0 - 83
, multiplier = 0
- Mode
0 - 84
, time unit = 3
Explanation:
Q
max
= max. flow in m
3
/h
B
= weir width in mm or m
K
= throat specific factor for above rectangular weir = 6290
h
max
= max. weir height in mm or m
k
= thickness of the weir in mm
3 - 4 x h
max
2 - 3 x h
max
≥
2 x h
max
B
45
°
Selection of the actual flow (Q)
Flow schedule for usual rectangular weir
B
Q
max
h
max
Q
min
h
min
in mm in m
3
/h
in mm
in m
3
/h
in mm
200
52,3
120
18,5
60
300
109,6
150
27,7
60
400
295,8
240
37,0
60
500
441,2
270
46,2
60
600
620,0
300
55,5
60
800
1519
450
73,9
60
1000
2923
600
92,4
60
1500
6128
750
138,7
60
2000
13535
1050
184,9
60
3000
34666
1500
277,3
60
If a rectangular weir acc. to above value is used, the value
for Q
max
can be taken out of the respective column and can
be used for programming of mode
0 - 82
…
0 - 84
.
Programming acc. to selection Q
max
= 13535 m
3
/h
-
Mode
0 - 82
, flow = 1353
-
Mode
0 - 83
, multiplier = 1
-
Mode
0 - 84
, time unit = 3
k
≈
3 mm
k
≈
3 mm
h
max
or