VEGA VEGASON 54P…56P Profibus PA User Manual
Page 61
VEGASON 54P … 56P
61
Technical data
Materials
Housing
PBT (Valox) or Aluminium
Process connection
- flange version
Alu or PP
- swivelling holder and thread
galvanized steel
Transducer
- VEGASON 54
PA (1.4301 with StEx)
- VEGASON 55, 56
UP
Transducer diaphragm
- VEGASON 54
1.4571
- VEGASON 55
Alu/PE foam
- VEGASON 56
Alu/PTFE non-stick coating
Transducer cable (cable cover)
- VEGASON 54, 55
PUR (1.1082)
- VEGASON 56
silicone (1.1083)
Weight (depending on the housing materials used)
VEGASON 54
- Version A
5.6 … 10.7 kg
- Version B
6.9 … 9.7 kg
- Version C
7.5 … 10.5 kg
- Version D
4.7 … 6.9 kg
VEGASON 55
- Version A
8.0 … 13.3 kg
- Version B
8.7 … 10.3 kg
- Version C
9.2 … 11.1 kg
- Version D
6.5 … 7.5 kg
VEGASON 56
- Version A
7.3 … 11.3 kg
- Version B
8.7 … 10.3 kg
- Version C
9.3 … 11.1 kg
- Version D
6.5 … 7.5 kg
CE conformity
VEGASON series 50 ultrasonic sensors meet the protective regulations of EMC
(89/336/EWG), NSR (73/23/EWG) and R & TTE directive (1999/5/EC).
Conformity has been judged acc. to the following standardst:
EN 300 683 - 1: 1997
EN 300 440 - 1: 1995
I-ETS 300-440
Expert opinion No. 0043052-01/SEE, Notified
Body No. 0499
EMC
Emission/Susceptibility
EN 61 326: 1997/A1: 1998
ATEX
EN 50 020: 1994
EN 50 018: 1994
EN 50 014: 1997
NSR
EN 61 010 - 1: 1993