beautypg.com

6 type code – VEGA VEGASON 54P…56P Profibus PA User Manual

Page 12

background image

12

VEGASON 54P … 56P

1.6 Type code

VEGASON 54 K EX.XX X X X X X X X

K -

Plastic housing PBT, M20 x 1.5 cable entry

N -

Plastic housing PBT,

½

" NPT cable entry

A -

Aluminium housing, M20 x 1.5 cable entry

FEP - Version A, flange DN 200 (PP)
FEA - Version A, flange DN 200 (Aluminium)
FLP - Version A, flange 8" (PP)
FLA - Version A, flange 8" (Aluminium)
SAS - Version B, flange swivelling holder DN 50
SBS - Version B, flange swivelling holder DN 80
GAS - Version C, flange swivelling holder DN 50
GBS - Version C, flange swivelling holder DN 80
RGS - Thread G 1 A
YYY - Other process fittings

X -

without display

A -

with integrated display

X -

without adjustment module MINICOM

B -

with adjustment module MINICOM (mounted)

A -

20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA (four-wire)

B -

20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA, HART

®

(four-wire)

E -

Power supply via signal conditioning instrument

G -

Segment coupler for Profibus PA

P -

90 … 250 V AC (only in USA)

N -

20 … 36 V DC, 24 V AC (only in USA)

Z -

Supply via signal conditioning instrument (only in USA)

.X -

without approval

EXS.X - StEx Zone 10

K -

Analogue 4 … 20 mA output signal (two-wire or
four-wire technology)

V -

Digital output signal (two-wire technology)

P -

Profibus

Type 54 - Measuring range 1.0 … 25 m
Type 55 - Measuring range 0.8 … 45 m
Type 56 - Measuring range 1.6 … 70 m

Measuring principle (SON for ultrasonic)

Product description