Veris Industries V200 SERIES Datasheet User Manual
Enclosed victory relays: 10a spdt, Great for external mount applications, Year

REL
AY
S
VERIS INDUSTRIES
800.354.8556
+1 503.598.4564
www.veris.com
Enclosed Victory Relays:
10A SPDT
DESCRIPTION
Victory 100 and 200 Series 10A enclosed relays are pilot-duty relays in an easy-
to-use nipple mount enclosure. The V100/V200 Series provide quick relay mounting
without a dedicated field enclosure, making them ideal for retrofit projects. Field-
selectable high and low voltage coil inputs provide on-site versatility.
APPLICATIONS
●
Command contactors
●
Control motors
●
Isolation
●
Device interlocking
●
Relay logic
●
Sense voltages for alarm conditions
FEATURES
●
Sleek field enclosure reduces the need for panel space
●
The nipple mount feature allows the Victory Series to be mounted to any
electrical enclosure
●
Flexible tinned stranded wire...fits easily in tight spaces & provides secure
connections to wire nuts
●
UL508 Listed...designed and approved for field installation...makes electrical
inspection a snap
●
Run low voltage instead of line voltage...eliminate conduit in some applications
SPECIFICATIONS
Operating Temperature Range:
V100, V100DC, V200
-34° to 60°C (-29° to 140°F)
V100D, V200D
-40° to 55°C (-40° to 131°F)
Operating Humidity Range
10-90% RH non-condensing
Expected Relay Life
Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles
Relay Status
LED ON=energized
Wire Specifications:
Lead Length
14” (356 mm) min.
Gauge
UL1015; Coil: 18 AWG; Contacts: 16 AWG
Insulation Class
600VAC RMS
Agency Approvals
UL 508
Great For External
Mount Applications
Pull in Voltage
AC
DC
10-30V..................................... 8
9
120V........................................ 78
208-277V................................. 154
Drop Out Voltage
AC
DC
10-30V..................................... 2 3
120V........................................ 18
208-277V................................ 36
Voltage
Coil Current
AC DC
10V.......................................... 25mA 14mA
12V.......................................... 25mA 14mA
24V.......................................... 31mA 16mA
30V.......................................... 39mA 18mA
120V........................................ 22mA
-
208V........................................ 19mA
277V........................................ 25mA
TYPICAL COIL PERFORMANCE
CONTACT RATINGS
Resistive.............. 10A@277VAC, 28VDC
Motor.................... 120VAC, 1/3HP N.O. & 1/6HP N.C.
240VAC, 1/3HP N.O. & 1/6HP N.C.
277VAC, 1/4HP N.O. & 1/8HP N.C.
Pilot Duty............. 277VAC, (1.7A), 480VA N.O.
Ballast.................. 277VAC, 1.7A
Tungsten............... 120VAC, TV3 N.O. TV2 N.C.
Gold Flash............. Yes
Year
Warranty
5
V100
V200D
VICTORY 100 & 200 SERIES
Year
Warranty
5
HQ0001833.B 01131