Veris Industries PH SERIES Datasheet User Manual
Digitally controlled gauge pressure transducer, Three switch-selectable ranges with test mode, Ph series
PRESSURE
VERIS INDUSTRIES
800.354.8556
+1 503.598.4564
www.veris.com
SPECIFICATIONS
Product:
Input Power
12 to 30VDC/24VAC
Output
3-wire transmitter; user selectable 4-20mA (clipped and capped)/0-5V/0-10V*
Accuracy
±1% F.S. Combined linearity, hysteresis, and repeatability
Surge Damping
Electronic; 5-second averaging
Test Mode
Overrides output to full-scale (20mA, 5V, 10V)
Pressure Ranges:
0-100 psi
25/50/100 psig switch selectable
0-250 psi
62.5/125/250 psig switch selectable
0-500 psi
125/250/500 psig switch selectable
0-1000 psi
250/500/1000 psig switch selectable
Product Operating Environment
-10° to 55°C (-4° to 130°F); 0 to 90% RH non-condensing
Long Term Stability
±0.25% per year
Zero Adjust
Pushbutton auto-zero and digital input (2-pos terminal block)
Status Indication
Dual-color LED: Green = Normal, Red = Overpressure, Flashing Red = Fault
Housing Material
White powder-coated steel
Sensor:
Media Compatibility
media compatible with 17-4 PH stainless steel
Proof Pressure
Max. 2x F.S. range
Burst Pressure
Max. 5x F.S. range
Temperature Compensated Range
0° to 50°C (32° to 122°F)
Media Temperature Limits
-20° to 85°C (-4° to 185°F); 0 to 90% RH noncondensing
Fittings
1/4" NPT male thread, 17-4 PH stainless
*Minimum input voltage for 4-20mA operation:
250 Ω loop (1-5V) = 12VDC
500 Ω loop (2-10V) = 15VDC
DESCRIPTION
The PH Series pressure transducers are designed for steam, air, gas, and liquid
pressure measurement in all media compatible with 17-4 PH stainless steel. They
utilize a microprocessor controlled sensor profiled for exceptional accuracy and
reliability. All models feature three switch-selectable ranges and a “test mode” to
verify wiring and panel input scaling. A pushbutton and digital input terminal is
used to automatically zero the output, and the microprocessor safeguards against
accidental zero adjustment during operation. The field-selectable output, offering
options of 0-5V, 0–10VDC, or 4-20mA, ensures excellent systems compatibility.
Jumper controlled surge damping is provided on all models to prevent false alarms.
APPLICATIONS
●
Chilled and hot water pump monitoring
●
HVAC and industrial gas monitoring
●
Instrument air pressure
●
Hydraulic oil pressure
FEATURES
●
Micromachined silicon sensor design...improves overpressure capacity and
prevents failures
●
Electronic surge damping for high stability
●
Pushbutton zero calibration...no trim pots to adjust, saves installation time
●
Switch-selectable pressure ranges...fewer models to order and stock
●
Pushbutton and remote zero adjustment...maintain accuracy and prevent
callbacks with automatic zero calibration
Microprocessor controlled signal conditioning (see graph)
●
Noise rejection reduces fluctuating readings due to noise or turbulence
●
Surge damping prevents false alarms by averaging fast peaks
●
Output clamping protects controller input from overcurrent/overvoltage
●
Test mode overrides the output to full scale...helps to diagnose wiring problems
Three Switch-Selectable
Ranges With Test Mode
Digitally Controlled Gauge
Pressure Transducer
PH
PH SERIES
HQ0001825.B 01131