INSTALLATION GUIDE
NETWORK VARIABLE DETAILS
Name
Type
Range
Description
nv1
nvoEgyWH
0-1e38kWH
Total Accumulated Energy
nv2
nvoPower
0-1e38kW
Power
nv3
nvoVAR
0-1e38kW
Reactive Power
nv4
nvoVA
0-1e38kW
Apparent Power
nv5
nvoPF
0-1
Power Factor
nv6
nvoLLVolts
0-1e38V
Voltage, Line to Line
nv7
nvoLNVolts
0-1e38V
Voltage, Line to Neutral
nv8
nvoAmps
0-1e38A
Amps
nv9
nvoAPower
0-1e38kW
Power, Phase A
nv10
nvoBPower
0-1e38kW
Power, Phase B
nv11
nvoCPower
0-1e38kW
Power, Phase C
nv12
nvoAPF
0-1
Power Factor, Phase A
nv13
nvoBPF
0-1
Power Factor, Phase B
nv14
nvoCPF
0-1
Power Factor, Phase C
nv15
nvoABVolts
0-1e38V
Voltage, Phase A to Phase B
nv16
nvoBCVolts
0-1e38V
Voltage, Phase B to Phase C
nv17
nvoACVolts
0-1e38V
Voltage, Phase A to Phase C
nv18
nvoANVolts
0-1e38V
Voltage, Phase A to Neutral
nv19
nvoBNVolts
0-1e38V
Voltage, Phase B to Neutral
nv20
nvoCNVolts
0-1e38V
Voltage, Phase C to Neutral
nv21
nvoAAmps
0-1e38A
Amperage, Phase A
nv22
nvoBAamps
0-1e38A
Amperage, Phase B
nv23
nvoCAmps
0-1e38A
Amperage, Phase C
nv24
nvoDmdSubInt
0-1e38kW
Present Real Subinterval Demand
nv25
nvoCurrDmd
0-1e38kW
Current Real Demand
nv26
nvoPeakDmd
0-1e38kW
Peak Real Demand
nv27
nvoRDmdSubInt
0-1e38kW
Present Reactive Subinterval Demand
nv28
nvoRCurrDmd
0-1e38kW
Current Reactive Demand
nv29
nvoRPeakDmd
0-1e38kW
Peak Reactive Demand
nv30
nviSubIntLen
0-65535
* Length of Subinterval multiplied by 5 sec.
nv31
nviNumSubInts
0-6
* Number of Subintervals per Demand
nv32
nviCommand
0-65535
* Command Register
nv33
nviMeterIndex
1-63
Selects Modbus address
nv34
nvoMeterIndex
1-63
Reports selected Modbus address
nc49
nciMaxSendT
0.0-6553.4 sec
Maximum time between nvoPower updates. Default is 0 sec (disabled).
nc52
nciMinSendT
0.0-6553.4 sec
Minimum time between nvoPower updates. Default is 15 sec.
nc88
nciMinDelta
0.0-100.0%
Percent change in nvoPower that will force an nvoPower update. Default is 5%. Set to 0.0% to disable.
nc49
nciMaxSendTg
0.0-6553.4 sec
Maximum time between updates to all network variables. Default is 0 sec (disabled).
* See H8163-CB documentation for further details. Do not bind to these meter configuration variable, because demand calculation restarts each time the meter writes these variables, and bound
variables are re-written at regular intervals.