Hu midit y, Ordering information, Application/wiring diagrams – Veris Industries HW SerieS Datasheet User Manual
Page 2: Accessories

HU
MIDIT
Y
800.354.8556
+1 503.598.4564
www.veris.com
ORDERING INFORMATION
HW Current Output (2-Wire, 4-20mA)
HW Voltage Output (3-Wire, 0-5V/0-10V)
APPLICATION/WIRING DIAGRAMS
* In order for unit to display both temp and RH, use the TA or D
temp selection.
Temp displayed on LCD is read from temperature transmitter, not
resistive element. If only the resistive output is selected for temp.
output, LCD will not display temp.
ACCESSORIES
Replacement humidity element (HS)
Replacement covers for wall units (AA51, AA51B, AA52,
AA52B)
Replacement cloud white wall housing (AA55)
Available
Examples:
HW L 2 N C T A
Stop Here
HW X 5 X S X
HW L 2 N C T C 2 2 F
Stop Here
NIST
US or EU
Temp.
Sensor Type
Display Accuracy
S = Standard
C = CE
A = Transmitter: 10° - 35°C (50° - 95°F
and 0° - 50°C (32° - 122°F) (switchable)
B = 100R Platinum, RTD
C = 1k Platinum, RTD
D = 10k T2, Thermistor
E = 2.2k, Thermistor
F = 3k, Thermistor
G = 10k CPC, Thermistor
H = 10k T3, Thermistor
J = 10k Dale, Thermistor
K = 10k with 11k shunt, Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm TAC, Thermistor
Q = 1uA/C, Linitemp
R = 10k US, Thermistor
S = 10k 3A 221
T = 100k, Thermistor
U = 20k “D”, Thermistor
W = 10k T2 high accuracy, Thermistor
Y = 10k T3 high accuracy, Thermistor
Z = 10k E1, Thermistor
1 = 1%
2 = 2%
3 = 3%
5 = 5%
= No
HW
Temp Cal Cert
Option
Value
A = 1k
F = 10k
G = 20k
K = 50k
M =100k
Options Available
X = No Cert
1 = 1pt Cal
2 = 2pt Cal
1 = Push Button Override
2 = Set Point Slider
3 = Push Button Override
and Set Point Slider
T = Temp*
X = No Temp
(Stop here)
N = NIST
(1% and 2% only)
X = No
(2%, 3%, and 5% only)
X
NIST
US or EU
Temp.
Sensor Type
Display Accuracy
S = Standard
C = CE
None = Select for TA temp option only
B = 100R Platinum, RTD
C = 1k Platinum, RTD
D = 10k T2, Thermistor
E = 2.2k, Thermistor
F = 3k, Thermistor
G = 10k CPC, Thermistor
H = 10k T3, Thermistor
J = 10k Dale, Thermistor
K = 10k with 11k shunt, Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm TAC, Thermistor
Q = 1uA/C, Linitemp
R = 10k US, Thermistor
S = 10k 3A 221
T = 100k, Thermistor
U = 20k “D”, Thermistor
W = 10k T2 high accuracy, Thermistor
Y = 10k T3 high accuracy, Thermistor
Z = 10k E1, Thermistor
1 = 1%
2 = 2%
3 = 3%
5 = 5%
= LCD
HW
Temp Cal Cert
Option
Value
A = 1k
F = 10k
G = 20k
K = 50k
M =100k
Options Available
X = No Cert
1 = 1pt Cal
2 = 2pt Cal
1 = Push Button Override
2 = Set Point Slider
3 = Push Button Override
and Set Point Slider
N = NIST
(1% and 2% only)
X = No
(2%, 3%, and 5% only)
T = Temp*
TA = Transmitter
only
D = Transmitter
and resistive
element
X = No Temp
(Stop here)
L
POWER SOURCE
12-30VDC/24VAC
CONTROL SYSTEM
COMMON
RH INPUT 0-10V
T INPUT 0-10V
RTD/ THERMISTOR/OVERRIDE
SETPOINT SLIDER
PWR
COMMON
RH OUT
T OUT
RTD/T
hermist
or/O
verride
RTD/T
hermist
or/O
verride
Slider R
igh
t
Slider L
ef
t
Slider W
iper
POWER SOURCE
12-30VDC only
CONTROL SYSTEM
PWR (4-20 SEND
)
RH OUT (4-20 R
TN)
T OUT (4-20 R
TN)
RTD/T
hermist
or/O
verride
RTD/T
hermist
or/O
verride
Slider R
igh
t
Slider L
ef
t
Slider W
iper
+
-
-
COMMON
RH RETURN
T RETURN
RTD/THERMISTOR/OVERRIDE
SETPOINT SLIDER
HS
Housing
Blank =
Cloud white
B = Black
Housing
Blank =
Cloud white
B = Black
HQ0001791.B 01131