beautypg.com

Veris Industries H40 SERIES Datasheet User Manual

Field mount motor control device, H40 series, Current monit oring

background image

current monit

oring

VERIS INDUSTRIES

800.354.8556

+1 503.598.4564

www.veris.com

DESCRIPTION

The Hawkeye 40 Series combines a switching relay, a current status sensor, and a

Hand-Off-Auto (HOA) switch into a single nipple-mounted housing. The low voltage

and line voltage wires are functionally separated from each other. A hinged lid on the

low voltage side allows easy relay connection and trip point adjustment, while the

high voltage side is closed for added safety. The H40 is connected in series between

the power source and the motor, and the relay and HOA switch control the on/off

functioning of the motor.

APPLICATIONS

Monitoring status and controlling small motor loads that are not driven by a

motor starter or contactor

• Exhaust fans

• Unit ventilators

• Fan terminal units

• Fan coil units

• Recirculating pumps

FEATURES

Separate high and low voltage sections...fast and economical installation by

low voltage electricians

Combines status sensor, command relay, and HOA switch in a single series

circuit...one line connection for three devices

Remote mounted enclosure eliminates the need to cram multiple devices into a

junction box

HOA provides true relay control...ideal for troubleshooting control wiring

SPST relay is field-selectable for N.O. or N.C. operation (some models)

5-year warranty

Line and Low Voltage

Separated Fractional Motor

Status with Command Relay

Field Mount Motor

Control Device

SPECIFICATIONS

Sensor Power (H40NE8A and H40ME8X only) Induced

Operating Temperature Range

-15°C to 50°C (5° to 122°F)

Operating Humidity Range

0-95% RH non-condensing

Frequency Range

50-60 Hz

Wire to Relay Contacts

H40 NE8A, H40NEXA, H40ME8X, H40MEXX: use 12 AWG (3.3 mm

2

) or larger wire

H40BAXA, H40AAXX: use 16 AWG (1.3 mm

2

) or larger wire

Low Voltage Terminal Block Wire Size

24-14 AWG (0.2 to 2.1 mm

2

)

Low Voltage Terminal Block Torque

3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)

Relay:

Relay Contact Ratings

H40NE8A, H40NEXA: 16A@120/250VAC, 12A@277VAC, 1HP@120VAC, 8A@28VDC

H40ME8X, H40MEXX: SPDT 16A@120/277VAC, 1HP@120VAC, 2HP@277VAC, 16A@28VDC

H40BAXA: 10A@120/240/277VAC, 1/3HP@120VAC, 8A@28VDC

H40AAXX: SPDT 10A@120/240/277VAC, 1/3HP@120VAC, 10A@28VDC

Relay Coil Ratings

H40NE8A, H40ME8X, H40MEXX, H40NEXA: 24VDC 45mA nom.; 24VAC 78mA nom.; Class 2*

H40AAXX, H40BAXA: 10-30VAC@24-38mA; 10-30VDC@10-16mA; Class 2*

Agency Approvals

UL 508 open device listing

* In addition, coil input from other sources may be used as detailed in NEC 2008, Article 725.121.

Year

Warranty

5

H40

H40 SERIES

TM

HQ0001770.B 01131