Po wer/ener g y monit oring, Dimensional drawing ordering information, Mounting diagrams – Veris Industries E5x SERIES Datasheet User Manual
Page 2: Accessories, Din mount configuration screw mount configuration

p
o
wer/ener
g
y monit
oring
800.354.8556
+1 503.598.4564
www.veris.com
4.2”
(107mm)
3.6”
(91mm)
1.5”
(39mm)
2.3”
(59mm)
1.9”
(48mm)
1.8”
(45mm)
DIMENSIONAL DRAWING
ORDERING INFORMATION
3.6 “
(91 mm)
4.2 “
(107 mm)
0.2 “
(4 mm)
3.9“
(99 mm)
2.4 “
(61 mm)
+
+
+
4.3 “
(109 mm)
1.2 “
(31 mm)
0.3 “
(8 mm)
0.4 “
(10 mm)
MOUNTING DIAGRAMS
DIN Mount Configuration
Screw Mount Configuration
ACCESSORIES
NEMA 4X enclosure (AE012)
Fuse Kits with hi-interrupt capability AC Fuses (AH02, AH03, AH04)
Split-core and solid-core CTs (H681x, SCT)
Replacement mounting clips (AE004)
E51Cx only
E50B1
E50C2
E50C3
E50F2
E50F5
E50H2
E50H5
E51C2
E51C3
E51H2
E51H5
MEASUREMENT CAPABILITY - FULL DATA SET
Bi-directional Energy Measurements
n
n
n
n
Power (3-phase total and per phase): Real (kW)
Reactive (kVAR), and Apparent (kVA)
n
n
n
n
n
n
n
n
n
n
n
Power Factor: 3-phase average and per phase
n
n
n
n
n
n
n
n
n
n
n
Present Power Demand: Real (kW),
Reactive (kVAR), and Apparent (kVA)
n
n
n
n
n
n
n
n
n
n
n
Import and Export totals of Present Power Demand:
Real (kW), Reactive (kVAR), and Apparent (kVA)
n
n
n
n
Peak Power Demand: Real (kW),
Reactive (kVAR), and Apparent (kVA)
n
n
n
n
n
n
n
n
n
n
n
Current (3-phase average and per phase)
n
n
n
n
n
n
n
n
n
n
n
Voltage: Line-Line and Line-Neutral
(3-phase average and per phase)
n
n
n
n
n
n
n
n
n
n
n
Frequency
n
n
n
n
n
n
n
n
n
n
n
ANSI 12.20 0.5% accuracy, IEC 62053-22 Class 0.5S
n
n
n
n
n
n
n
ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
n
n
n
n
Accumulated Net Energy: Real (kWh),
Reactive (kVARh), and Apparent (kVAh)
n
n
n
n
n
n
n
n
n
n
n
Accumulated Real Energy by phase (kWh)
n
n
n
n
n
n
n
n
n
n
n
Import and Export Accumulators of
Real and Apparent Energy
n
n
n
n
Reactive Energy Accumulators by Quadrant
(3-phase total and per phase)
n
n
n
n
Demand Interval Configuration:
Fixed or Rolling Block
n
n
n
n
n
n
n
n
n
n
n
Demand Interval Configuration:
External Sync to Comms
n
n
n
n
n
n
n
n
n
n
DATA LOGGING:
Data Logging: 10 16-Bit Configurable
(can include Date/Time) Data Buffers
n
n
Data Logging: 3 Timestamped 32-Bit
Configurable Data Buffers
n
n
n
Store up to 60 days of readings
at 15-minute intervals
n
n
n
n
n
OUTPUTS:
Alarm Output (N.C.)
n
n
n
n
n
n
n
n
1 Pulse Output (N.O.)
n
n
n
n
2 Pulse Outputs (N.O.)
n
RS-485 Serial (Modbus RTU Protocol)
n
n
n
n
RS-485 Serial (BACnet MS/TP Protocol)
n
n
n
n
LON FT Serial (LonTalk Protocol)
n
n
INPUTS:
2 Pulse Contact Accumulator Inputs
n
n
n
1 Pulse Contact Accumulator Input
n
n
n
AH04
AE012
AV01/AV02
(clip styles may vary)
U013-0012
U013-0013
H8932/H8936
DIN Rail (AV01), DIN Rail Stop Clips (AV02)
Modbus TCP Gateway (U013-0012)
BACnet IP Router (U013-0013)
Network Display (H8932, H8936)
NEW
NEW
®
T
E
S
T
I
N
G
L
A B O R
A
T
O
R
I
E
S
· B
A C n e t ·
E5xH2 only
NEW
E50Fx only
HQ0001710.H 09132