beautypg.com

4 auto make clip for cam d, 5 auto make clip for cam e, 6 resync to tc ref – EVS XSense Version 10.03 - July 2010 Configuration Manual User Manual

Page 55: 7 guardbands, Auto make clip for cam d, Auto make clip for cam e, Resync to tc ref, Guardbands

background image

Issue
10.03.A

XSense – Version 10.03 – Configuration Manual

EVS Broadcast Equipment SA – July 2010

48

3.8.4 A

UTO

M

AKE

C

LIP FOR

CAM

D

Possible values: Yes (default) / No

Make clip on CAM D even if no IN or OUT point has been marked on this one.

3.8.5 A

UTO

M

AKE

C

LIP FOR

CAM

E

Possible values: Yes (default) / No

Make clip on CAM E even if no IN or OUT point has been marked on this one.

3.8.6 R

ESYNC TO

TC

R

EF

The Multicam application uses an internal table to reference all timecode

discontinuities detected on the LTC input of the system. This table is used to
match a recorded field to its timecode. When the number of TC discontinuities is
too important, a “!TC” warning appears on the OSD of the output monitors and the
system switches to the “internal timecode mode. The operator can clear the TC
discontinuities by calling the Resync to TC ref function. This function

synchronizes the internal TC to the timecode read on the LTC input of the server.
From that moment on, the system will assume that the timecode was continuous
for previously recorded material, and will take into account the new timecode
discontinuities.

Note that the above explanation is only valid for record trains. For clips, the

timecode of the first field of the clip is memorized at the creation of the clip, and
the timecode is always assumed continuous inside the clip. Clearing the internal
TC table will consequently have no effect on the timecode of recorded clips.

To call the Resync to TC ref function, simply press the F6 key. The function is
immediately performed and the message “TC resynchronization done”

is displayed.


Record Trains p.2.2
[F1]Guardbands : 05s00fr

[F2]Default clip duration : 04s00fr

[F3]Mark cue points : Live
[F4]Preroll : 02s00fr
[F5]Record trains OUTs : Play Through
[F6]Freeze on cue points : No

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

3.8.7 G

UARDBANDS

Range: from 00s00fr to 60s00fr. Default: 05s00fr

This option specifies the amount of «guardband» before and after clips.