Troubleshooting, Error messages (general) – ACU-RITE 100S User Manual
Page 26

100S General Purpose Reference Manual
23
Troubleshooting
A
ROM memory error has occurred. Press the
CLEAR
key to acknowledge the error. If the system does not oper-
ate properly, contact your
100S GP
distributor for repair/
replacement procedures.
A power loss has occurred. This message will appear
everytime you power up the system and can be cleared
by pressing the
CLEAR
key. If the E1 message appears at
any time other than at power up, a power interruption has
occurred and your current position may be lost. Reestab-
lish the datum if necessary. If the problem persists, con-
tact your distributor for repair/replacement procedures.
A random access memory (RAM) error has occurred.
Press the
CLEAR
key to acknowledge the error. If the sys-
tem does not operate properly, contact your
100S GP
dis-
tributor for repair/replacement procedures.
A scale miscount error (invalid waveform) has occurred.
The E9 message will appear on the axis that has the error.
Press
CLEAR
to reset the axis(es). Your current position
may be lost. Re-establish the datum if necessary. If the
system does not operate properly, contact your
100S GP
distributor for repair/replacement procedures.
Error Messages (General)
E1
E2
E3
E4
E9
When
100S GP
is powered up, it will run a series of tests to ensure that
the software is working properly. If an error message appears, refer to
the charts below for a diagnosis and solution.
An EEPROM memory error has occurred. Press the
CLEAR
key to acknowledge the error. The datum and
setup information may be lost. These areas should be
checked and reestablished upon power up. If the problem
persists, contact your distributor for repair/replacement
procedures.