Troubleshooting – ACU-RITE 100S User Manual
Page 23

20
100S General Purpose Reference Manual
Troubleshooting
Keys not
working
properly
Error
messages (E2-
E56) appear
Causes vary
Invalid keypress
Turn the system “off” and
then “on” again, using the
switch on the back of the
readout.
If an error (besides E1) is
still detected when the sys-
tem is powered up, contact
your
100S GP
distributor
for repair/replacement
procedures. Refer to pgs.
23 - 24 for a list of error
messages.
Dashes
appear on
screen
Move the axis toward the
“0” position. As the scale
counts down, the display
will show the correct
position.
Display overflow
Turn the system “off” and
then “on” again, using the
switch on the back of the
readout. If an error (be-
sides E1) is detected when
the system is powered up,
contact your
100S GP
distributor for repair/
replacement procedures.
Refer to pg. 23-24 for a list
of error messages.
Error
message (E1)
appears
Power loss occurred
This is a normal message
at power up. If the mes-
sage appears at any other
time during operation, a
problem may have oc-
curred. Refer to pg. 23 for
details.
Symptom
Probable Cause
Recommended
Corrective Action