Setup

Linear Error Compensation

With 100S GP, you can compensate for machine tool wear. If you know
the linear error compensation (LEC) value in parts-per-million (PPM),
you can enter it directly.

If you don’t know the LEC, use the formula on the next page to deter-
mine the value for each axis.

To change the linear error compensation:

Move to the “Linear Error Compensation” display in the Setup mode.
(Press SETUP and then the ENTER key until “LEC” (appears).

Press the X or Z key for the axis you want to change. 100S GP will
display the current LEC value for that axis.

Using the keypad, enter the linear error compensation factor (in
PPM), followed by the ± key for negative values. The number must
be within -9999 and 9999 (use whole numbers). The formula for
calculating the value is on the next page.

After you complete setting your LEC, press ENTER to continue with
setup or press ENTER then SETUP to return to the normal DRO
display.