Improper wiring
Compare the wiring to
the "normally closed"
and "normally open" con-
tacts for that connector,
as described in the manu-
al. Rewire as needed.
Symptom
Probable Cause
Recommended
Corrective Action
Each wire must be
secured under the corre-
sponding screw.
Disconnect power to
MILLPWR
and the AMI.
Completely loosen each
screw on the connector.
Reinsert each wire one
by one, retightening each
screw as you do so.
One or more wires not
secure in the J2 connector
Output devices not
responding/not
responding proper-
ly (cont’d)
Output not functioning
correctly
Check the auxiliary func-
tion steps within the pro-
gram and verify that the
information in each step
is correct.