ACU-RITE MILLPWR Auxiliary User Manual
Page 28

AMI Reference Manual
25
•
Press the MORE STEPS softkey two more times.
•
Press the AUXILIARY FUNCTIONS softkey.
•
Highlight the auxiliary relay(s) that you want to
program. (The “AUX” numbers in each field cor-
respond with the number on the AMI.) Select
from the OFF, ON, and PULSED softkeys for each.
ON The AMI output contacts will
switch to an energized state.
OFF
The AMI output contacts will
switch to their default (de-ener-
gized) states.
PULSED The AMI output contacts will
switch to an energized state for
the length of time that you define.
Display User Prompt The AMI allows the operator, if desired,
to pause the step before or after the
relays are turned on or off.
•
If you selected PULSED, then enter the amount of time (in seconds or
tenths of seconds) that you want the relay to remain on. The maximum
amount of time that a relay can pulse is 999.9 seconds.
Note: Pulse mode must time out before the steps of the program can
continue.
•
Set the Display User Prompt for the step to pause before or after by
pressing either the BEFORE STEP, AFTER STEP. If you choose not to
include a pause, press the NO softkey.
Note: The auxiliary function relays will not turn off automatically
during an Operator Intervention Message (OIM).
•
Pressing YES for the Set Continuous field allows an Auxiliary Function
Step to be entered (e.g. activate coolant) without interrupting the continu-
ous milling path.
•
Press the
USE
key.