Set the picc operating parameter, Table 40, Response format (1 byte) – ACS AET62 NFC Reader with Fingerprint Sensor User Manual
Page 21: Table 41, Command format (5 bytes), Table 42, Table 43, Picc operating parameter. default value = ff

Response
Data Out
Result
PICC Operating Parameter
Table 40: Response Format (1 byte)
7.5. Set the PICC Operating Parameter
This is used to set the PICC Operating Parameter of the reader.
Command
Class
INS
P1
P2
Le
Get
Response
0xFF 0x00
0x51
New PICC
Operating
Parameter
0x00
Table 41: Command Format (5 Bytes)
Response
Data Out
Result
PICC Operating Parameter
Table 42: Response Format (1 byte)
Bit Parameter
Description
Option
7
Auto PICC Polling
To enable the PICC Polling
1 = Enable
0 = Disable
6
Auto ATS Generation
To issue ATS Request whenever an
ISO14443-4 Type A tag is activated
1 = Enable
0 = Disable
5 Polling
Interval
To set the time interval between
successive PICC Polling.
1 = 250 ms
0 = 500 ms
4 FeliCa
424K
1 = Detect
0 = Skip
3 FeliCa
212K
1 = Detect
0 = Skip
2 Topaz
1 = Detect
0 = Skip
1
ISO14443 Type B
1 = Detect
0 = Skip
0
ISO14443 Type A
#To detect the Mifare
Tags, the Auto ATS
Generation must be
disabled first.
The Tag Types to be detected
during PICC Polling.
1 = Detect
0 = Skip
Table 43: PICC Operating Parameter. Default Value = FF
Document Title Here
Document Title Here
Document Title Here
AET62 Reference Manual
Version 1.00
Page 21 of 35
www.acs.com.hk