Get the firmware version of the reader, Get the picc operating parameter, Table 34 – ACS AET62 NFC Reader with Fingerprint Sensor User Manual
Page 20: Table 35, Status code, Table 36, Current led state (1 byte), Table 37, Command format (5 bytes), Table 38

Data In: Blinking Duration Control
Byte 0
Byte 1
Byte 2
Byte 3
T1 Duration
Initial Blinking State
(Unit = 100ms)
T2 Duration
Toggle Blinking State
(Unit = 100ms)
Number of
repetition
0x00
Table 34: Bi-Color LED Blinking Duration Control Format (4 Bytes)
Data Out: SW1 SW2. Status Code returned by the reader.
Results
SW1
SW2
Meaning
Success 90
Current LED
State
The operation is completed successfully.
Error
63 00
The operation is failed.
Table 35: Status Code
Status Item Description
Bit 0
Current Red LED
1 = On; 0 = Off
Bit 1
Current Green LED
1 = On; 0 = Off
Bits 2 – 7
Reserved
Table 36: Current LED State (1 Byte)
Note:
The LED State operation will be performed after the LED Blinking operation is completed.
The LED will not be changed if the corresponding LED Mask is not enabled.
The LED will not be blinking if the corresponding LED Blinking Mask is not enabled. Also, the
number of repetition must be greater than zero.
T1 and T2 duration parameters are used for controlling the duty cycle of LED blinking. For
example, if T1=1 and T2=1, the duty cycle = 50%. #Duty Cycle = T1 / (T1 + T2).
7.3. Get the Firmware Version of the reader
This is used to retrieve the firmware version of the reader.
Command
Class
INS
P1
P2
Le
Get
Response
0xFF 0x00
0x48
0x00
0x00
Table 37: Command Format (5 Bytes)
Response
Data Out
Result Firmware
Version
Table 38: Response Format (10 bytes)
E.g. Response = 41 45 54 36 32 30 33 30 30 (Hex) = AET620300 (ASCII)
7.4. Get the PICC Operating Parameter
This is used to retrieve the PICC Operating Parameter of the reader.
Command
Class
INS
P1
P2
Le
Get
Response
0xFF 0x00
0x50
0x00
0x00
Table 39: Command Format (5 Bytes)
Document Title Here
Document Title Here
Document Title Here
AET62 Reference Manual
Version 1.00
Page 20 of 35
www.acs.com.hk