6.3. Read Binary Blocks
The “Read Binary Blocks command” is used for retrieving “data blocks” from the PICC. The data
block/trailer block must be authenticated first.
Command
Class INS
P1
P2
Le
Read Binary Blocks
FF
B0 00
Block Number
Number of Bytes to
Read
Table 16: Read Binary APDU Format (5 Bytes)
where:
Block Number (1 Byte): The block to be accessed
Number of Bytes to Read (1 Byte): Maximum 16 bytes
Response
Data Out
Result
0 <= N <= 16
SW1 SW2
Table 17: Read Binary Block Response Format (N + 2 Bytes)
Results
SW1
SW2
Meaning
Success 90 00
The operation completed successfully.
Error 63
00
The operation failed.
Table 18: Read Binary Block Response Codes
Example:
1. Read 16 bytes from the binary block
0x04
(Mifare 1K or 4K)
APDU = {FF B0 00
04
10
}
2. Read 4 bytes from the binary Page
0x04
(Mifare Ultralight)
APDU = {FF B0 00
04
04
}
3. Read 16 bytes starting from the binary Page
0x04
(Mifare Ultralight) (Pages 4, 5, 6 and 7 will
be read)
APDU = {FF B0 00
04
10
}
Document Title Here