Removal, A. elt removal, Figure 12. elt removal sequence – ACR&Artex C406-N User Manual
Page 53
25-62-13
Page 53 of 109
MAR 1/13
ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-N (453-5060), C406-N HM (453-5061)
REMOVAL
TASK 25-62-13-000-801
1. ELT
SUBTASK 25-62-13-010-001
A. ELT Removal
(1)
See "Figure 12. ELT Removal Sequence".
Figure 12. ELT Removal Sequence
(2)
Loosen the mounting frame cap thumbscrews.
(3)
Slide the mounting frame cap back away from the ELT.
(4)
Lift the protective top cover up, away from the ELT and set it aside.
(5)
Disconnect the antenna coax cable from the ELT.
(6)
Disconnect the harness receptacle from the ELT, if necessary.
NOTE: The receptacle may disconnect when the mounting frame cap is pulled back.
(7)
Lift the ELT up from the connector end.
NOTE: Careful use of a flat blade screwdriver as a lever will make this step easier.
(8)
Slide the ELT up and out, away from the mounting tray.
PROTECTIVE TOP
COVER ASSY
ELT MAIN
ASSEMBLY
MOUNTING
TRAY ASSY
MOUNTING FRAME
CAP ASSY
3
2
6
4
5
DISCONNECT COAX
CABLE
DISCONNECT
HARNESS
1
LOOSEN THUMBSCREW
(2 PLCS)
NOTE: Coax cable and
wiring harness not
shown for clarity.