beautypg.com

G. remote switch control panel functional test – ACR&Artex C406-N User Manual

Page 100

background image

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-N (453-5060), C406-N HM (453-5061)

25-62-13

Page 100 of 109

MAR 1/13

SUBTASK 25-62-13-750-001

G. Remote Switch Control Panel Functional Test

(1)

Coordinate functional testing of the remote switch control panel with the post-installation ELT

testing requirements in SUBTASK 25-62-13-750-001 on page 77.

(2)

Place the remote switch in the “ON” position.

(3)

Verify the cockpit remote switch panel light illuminates immediately. If the light fails to

illuminate immediately and stay on steady, recheck the interface wiring and connections

between the ELT and the remote switch control panel.

(4)

Place the remote switch in the “ARM” position.

(5)

Verify the ELT deactivates.