3 debug command sets, 4 configuring examples with at commands, Table 16 debug command sets – ZyXEL Communications ISDN Terminal Adapter Omni.Net Lite User Manual
Page 62

Omni.Net Lite User’s Guide
61
Chapter 3 Using AT Commands
3.3.3 Debug Command Sets
The AT command sets for debugging are shown in the following table.
3.4 Configuring Examples with AT Commands
This section shows you some examples of configuring the TA using AT commands.
!pS= number> [/ address>] Assign you phone number to the analog port. hyphen ( -), comma (,) and (‘,’). [‘,’] will be ignored. “A-Z”. $D99 Upgrade firmware. $C0? Display the charge information of the last call. $C1? Display the accumulative charge information of the calls. $F99 Reset all parameters to the factory defaults. $P5= selection code> Set three-digit country code for caller ID signaling (FSK or DTMF). Table 15 AT Command Sets for the Analog Port COMMAND DESCRIPTION Table 16 Debug Command Sets COMMAND DESCRIPTION #C0 Clear frame logs. #Dn Display frame logs or internal task status. L6=n Set the level of frame logs to Q.921. L8=n Set the level of frame logs to V.120, X.75. L13=n Set the level of frame logs to PPP.
p: enter 1 or 2 to specify the analog port.
Use $C0=0 to clear the information.
Use $C0=1 to clear the information.
The default is 216.
n=80: display frame logs.
n=82: display C/I code (layer 1 signal) logs.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.
n=0: disable frame logging.
n=1: enable signal frame logging.
n=2: enable full frame logging.