%D3=n
The number of retrying to re-dial the outgoing data call once TA
failed to establish the data call.
n=0: don't re-dial.
n=1~10: re-dial for n times until the call is established.
%Id= number> [/ address>] Create a list of the incoming call phone number via the data port. from 0 to 9, *, #, hyphen ( -), comma (,) and (‘,’). [‘,’] will be ignored. “0-9”,” a-z” and “A-Z”. %M1=n Enable/Disable PAP to CHAP conversion. %M2=n Enable/Disable "Dynamic Bandwidth Allocation for Voice Call". %M3=n Set threshold of data loading to add one channel, the unit is kbps. %M4=n Set a threshold of data loading to drop one channel, the unit is kbps. %M5=n Persist time for monitoring threshold to add or drop one channel, the unit is 5 seconds. %Od= Create a list of the outgoing call prefix digits for the data port. %P0=n Set incoming call screen mode for the data port. %P1=n Set outgoing call screen mode for the data port. (see %Od= (see %Od= Table 14 AT Data Command Sets Requiring an "AT" Prefix COMMAND OPTION DESCRIPTION
d=0-4.
n=0: Disable CHAP (default).
n=1: Enable CHAP.
n=0: Disable.
n=1: Enable (default).
n=0-64, the default is 35.
n=0-64, the default is 25.
n=1-255, the default is 24.
d=0-2.
n=0: Accept all incoming calls (default).
n=1: Reject all incoming calls.
n=2: Only accept the calls from the phone number in the list (see
%Id=
n=3: Only reject the calls from the phone number in the list (see
%Id=
n=0: No restriction (default).
n=1: Prohibit all outgoing calls.
n=2: Only accept the calls with the prefix in the pre-defined list
n=3: Only reject the calls with the prefix in the pre-defined list