North american isdn – ZyXEL Communications 2864I User Manual

Page 44

background image

Installation 31

North American ISDN

Figure 3-7 Menu 2 - ISDN Setup for North America

1. Switch Type - Verify the switch type information with your

telephone company. For North America, select the type of
switch used by your telephone company. If your switch type is
not currently shown, press the space bar to change to the next
switch; repeat until you see the correct switch type. The
Prestige will not be able to place or to receive calls if the wrong
switch type is specified. If you are not sure, contact your
telephone company to confirm the exact switch type.

2. B Channel Usage - If you are using one B channel of your

Prestige with another device on the S/T bus, then select
Switch/Unused. If not choose Switch/Switch.

3. Telephone Number(s) - Enter the telephone number(s)

assigned to your ISDN line by your telephone company. Some
switch types only have one telephone number. For North
America, these phone numbers should be in a standard seven
digit format e.g. 5551234. Note that the Prestige only accepts
digits; do not include - and spaces in this field. This field should
be no longer than 19 digits.

4. Analog Call - This tells the Prestige how to route an incoming

analog call. Set to Voice if you wish to route the incoming