Exit Setup Mode
To leave Setup Mode, complete these steps:
1.
Press
SETUP/EXIT
.
The LCD displays
SAVE CHANGES
.
2.
Press the Plus (+) or Minus (–) to display the save options (
3.
Press
NEXT/SAVE
to select the displayed choice.
When the configuration and calibration sequence is done,
PRINTER READY
displays.
Table 4 • Save Options When Leaving Setup Mode
LCD Display
Description
PERMANENT
Permanently saves the changes. Values are stored in the printer even when
power is turned off.
TEMPORARY
Saves the changes until you change them again or until power is turned off.
CANCEL
Cancels all changes from the time you pressed
SETUP/EXIT
except the
darkness and tear-off settings (if they were changed).
LOAD DEFAULTS
Sets all parameters other than the network settings back to the factory defaults.
Note •
Loading factory defaults causes the printer to auto-calibrate.
LOAD LAST SAVE
Loads values from the last permanent save.
DEFAULT NET
Sets the wired and wireless network settings back to factory defaults.