Special screens – Xantrex Technology GT3.0 User Manual
Page 84
Monitoring the Inverter
5–8
975-0131-01-01
Additional Fault
messages for all
systems
Additional message screens can be viewed in fault mode by tapping the Xantrex
logo near the LCD. Each additional tap displays the next screen in the order
shown in Table 5-9.
Special Screens
Special message screens are displayed in specific situations that are not
considered fault situations. They can appear in any mode of operation. These
screens are described in Table 5-10.
Table 5-9 Additional Fault Mode Screens
Tap
Display*
* In a multiple unit system with communications cables properly installed, the
system values displayed are for the entire system. Time online and array
readings are for the local inverter and PV array associated with that inverter.
Description
1st time
Current fault message
screen (see Table 5-8)
LCD backlight turns on for better readability.
2nd time
System 0W
Today 2.500kWh
Energy being produced by the system now.
Cumulative energy produced by the system
today.
3rd time
System Lifetime
305kWh
Lifetime energy produced by the GT Inverter
system.
4th time
Time Online
Today hh:mm:ss
Length of time inverter was online today, in
hours (hh), minutes (mm) and seconds (ss).
5th time
Array Readings
350.5V 8.4A
Immediate DC voltage and current readings of
power from the PV array.
6th time
Grid Readings
242.6V 60.0Hz
Immediate AC voltage and frequency readings
of power from the Grid.
Table 5-10 Special Message Screens
Display
Description
Reconnecting in
sss seconds
Time remaining in seconds (sss) before the GT Inverter
reconnects to the Grid. This is a protection timer; it runs for
approximately five minutes at startup and after any Grid fault.
Inverter
Offline
GT Inverter switching (or has switched) from Normal
Operation to Offline mode. This screen may flash alternately
with a Fault message screen.