beautypg.com

VIEWSONIC XGA LCD PROJECTOR pjl9371 User Manual

Page 65

background image

PJL9371

ViewSonic

60

Regarding the indicator lamps (continued)

• When the interior portion has become overheated, for safety

purposes, the projector is automatically shut down, and the indicator lamps

may also be turned off. In such a case, disconnect the power cord, and wait at

least 45 minutes. After the projector has sufficiently cooled down, please make

confirmation of the attachment state of the lamp and lamp cover, and then turn

the power on again.

NOTE

POWER TEMP

LAMP SECURITY

Description

Blinking

In

Red

or

Lighting

In

Red

Blinking

In

Red

Turned

off

Turned

off

The cooling fan is not operating.

Please turn the power off, and allow the projector

to cool down at least 20 minutes. After the projector

has sufficiently cooled down, please make

confirmation that no foreign matter has become

caught in the fan, etc., and then turn the power on

again.

If the same indication is displayed after the remedy,

please contact your dealer or service company.

Blinking

In

Red

or

Lighting

In

Red

Lighting

In

Red

Turned

off

Turned

off

There is a possibility that the interior portion

has become heated.

Please turn the power off, and allow the projector

to cool down at least 20 minutes. After the projector

has sufficiently cooled down, please make

confirmation of the following items, and then turn

the power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the remedy,

please set FAN SPEED of SERVICE item in

OPTION menu to HIGH.

Lighting

In

Green

Simultaneous

blinking in

Red

Turned

off

It is time to clean the air filter.

Please immediately turn the power off, and clean

or change the air filter referring to the section

“Cleaning and replacing the air filter”. After cleaning

or changing the air filter, please be sure to reset the

filter timer.

After the remedy, reset the power to ON.

Lighting

In

Green

Alternative

blinking in

Red

Turned

off

There is a possibility that the interior portion

has become overcooled.

Please use the unit within the usage temperature

parameters (5°C to 35°C).

After the treatment, reset the power to ON.

Troubleshooting