beautypg.com

Toshiba B-492L User Manual

Page 75

background image

APPENDIX 4 SYSTEM MODE

EO1-33032

A4.8 Additional Information

A4-25

A4.8.2

Maintenance Counter and Parameter Check Print Sample and Descriptions
(Cont.)

Descriptions of the Maintenance Counter

No. Item

Count

Condition

Range

(1) Total media distance covered

0.0 to 2000.0 km

(2) Media distance covered

Counted when the feed motor is driven to feed,
print and issue the media. (Also counted
during back feed.) See NOTE 6.

0.0 to 181.9 km

(3) Print distance

Counted while printing. (Back feeding is not
counted.) See NOTE 2.

0.0 to 200.0 km

(4) Head up/down count

Counts every print head up and down
movement using the ribbon saving solenoid.
(Up + down=1 count) See NOTE 3.

0 to 2000000 times

(5) Ribbon motor operating time

Counts when the ribbon motor is driven to feed,
print and issue media. (The driving time is also
counted during back feed.) See NOTE 4.

0 to 2000 hours

(6)

Head up solenoid operating
time

Counted during the ribbon saving.
See NOTE 4.

0 to 1000 times

(7) RS-232C hardware error count

Counted when a parity, overrun or framing
error occurs. See NOTE 5.

0 to 255 times

(8) System error count

Counted when any error occurs.

0 to 15 times

(9) Momentary power failure count

Counts the number of times the power restores
while the CPU is busy after reset.

0 to 15 times











Descriptions of the Parameters

No.

Item Contents

(10) Feed length fine adjustment (PC), (KEY)

-50.0 mm to +50.0 mm

(11) Strip position fine adjustment (PC), (KEY)

-50.0 mm to +50.0 mm

(12) Back feed length fine adjustment (PC), (KEY)

-9.9 mm to +9.9 mm

(13)

Print tone fine adjustment (Thermal transfer), (PC),
(KEY)

-10 step to +10 step

(14)

Print tone fine adjustment (Thermal direct), (PC),
(KEY)

-10 step to +10 step

(15)

Ribbon rewind motor driving voltage fine adjustment
(PC), (KEY)

-15 step to +0 step

(16)

Ribbon feed motor driving voltage fine adjustment
(PC), (KEY)

-15 step to +0 step

(17) Strip Motor driving speed fine adjustment (PC), (KEY) +0 to +4
(18) X axis fine adjustment

-99.5 mm to +99.5 mm

NOTES:

1. The item from (2) through (9) are initialized to “0” after RAM clear.
2. If the Print distance is 5.5m or less, it is rounded down and no data is added to the memory at power off.
3. If the count is 31 counts or less, it is rounded down and no data is added to the memory at power off.
4. If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory at power off.
5. When more than 1 byte-data is continuously sent, they are counted by byte.
6. If the media distance covered is 69.4 cm or less, it is rounded down and no data is added to the memory at

power off.