beautypg.com

Application information – Texas Instruments MSP430x11x1 User Manual

Page 40

background image

MSP430x11x1
MIXED SIGNAL MICROCONTROLLER

SLAS241C – SEPTEMBER 1999 – REVISED JUNE 2000

40

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

APPLICATION INFORMATION

Port P2, P2.3 to P2.4, input/output with Schmitt-trigger

EN

D

See Note 27

See Note 28

See Note 28

See Note 27

GND

VCC

P2.3

0

1

0

1

Interrupt

Edge

Select

EN

Set

Q

P2IE.3

P2IFG.3

P2IRQ.3

Interrupt
Flag

P2IES.3

P2SEL.3

Module X IN

P2IN.3

P2OUT.3

Module X

OUT

Direction Control

From Module

P2DIR.3

P2SEL.3

Pad Logic

0: Input

1: Output

Bus Keeper

CAPD.3

EN

D

See Note 27

See Note 28

See Note 28

See Note 27

P2.4

1

0

1

0

Interrupt

Edge

Select

EN

Set

Q

P2IE.4

P2IFG.4

P2IRQ.4

Interrupt
Flag

P2IES.4

P2SEL.4

Module X IN

P2IN.4

P2OUT.4

Module X OUT

Direction Control

From Module

P2DIR.4

P2SEL.4

Pad Logic

0: Input

1: Output

Bus Keeper

CAPD.4

_

+

Comparator_A

Reference Block

CAREF

CAREF

CAEX

P2CA

CAF

CCI1B

0 V

VCC

GND

APPLICATION INFORMATION

PnSel.x

PnDIR.x

Direction

control from module

PnOUT.x

Module X OUT

PnIN.x

Module X IN

PnIE.x

PnIFG.x

PnIES.x

P2Sel.3

P2DIR.3

P2DIR.3

P2OUT.3

Out1 signal†

P2IN.3

unused

P2IE.3

P2IFG.3

P1IES.3

P2Sel.4

P2DIR.4

P2DIR.4

P2OUT.4

Out2 signal†

P2IN.4

unused

P2IE.4

P2IFG.4

P1IES.4

† Signal from Timer_A
NOTES: 27. Optional selection of pullup or pulldown resistors with ROM (masked) versions.

28. Fuses for optional pullup and pulldown resistors can only be programmed at the factory (ROM versions only).