beautypg.com

Texas Instruments MSP430x11x1 User Manual

Page 14

background image

MSP430x11x1
MIXED SIGNAL MICROCONTROLLER

SLAS241C – SEPTEMBER 1999 – REVISED JUNE 2000

14

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

flash memory, timing generator, control register FCTL2 (continued)

The flash timing generator is reset with PUC. It is also reset if the emergency exit bit EMEX is set.

Control register FCTL2 may not be written to if the BUSY bit is set; otherwise, an access violation will occur
(ACCVIFG=1).

Read access is possible at any time without restrictions.

ACLK

0

1

2

3

SSEL1

MCLK

SMCLK

SMCLK

Divider,

1 .. 64

Reset

Flash Timing

Generator

SSEL0

FN5.......... FN0

fX

PUC

EMEX

BUSY

WAIT

Write ’1’ to

Figure 1. Flash Memory Timing Generator Diagram

FCTL2

012Ah

FN2

FN1

FN0

0

rw-0

rw-1

rw–0

7

rw–0

SSEL0

rw–1

FN5

FN4

FN3

15

FCTL2 read:

096h

FCTL2 write:

0A5h

rw-0

rw-0

rw-0

8

SSEL1

The control bits are:

FN0–FN5

012Ah, bit0–5

These six bits define the division rate of the clock signal. The division
rate is 1 to 64, according to the digital value of FN5 to FN0 plus one.

SSEL0, SSEL1

012Ah, bit6,7

Clock source select

0: ACLK
1: MCLK
2: SMCLK
3: SMCLK

The flash timing generator is reset with PUC. It is also reset if the EMEX bit is set.

flash memory control register FCTL3

There are no restrictions to modify this control register.

FCTL3

012Ch

KEYV

BUSY

0

r(w)-0

rw-(0)

rw–0

7

r0

res.

r0

EMEX

Lock

WAIT

15

FCTL3 read:

096h

FCTL3 write:

0A5h

rw-1

rw-1

rw-0

8

ACCV

IFG

res.