12-1-3. Cabling and Setting of Remote Controller Control
2-remote controller control (Controlled by two remote controllers)
One or multiple indoor units are controlled by two remote controllers.
(Max. 2 remote controllers are connectable.)
• 1 indoor unit is controlled by 2
remote controllers
(Setup method)
One or multiple indoor units are controlled by two remote controllers.
(Max. 2 remote controllers are connectable.)
How to set wired remote controller to sub remote
controller
Insert the remote controller address connector
provided on the rear side of the remote controller
switch P.C. board into Sub in exchange for Master.
How to set wireless remote controller to sub
remote controller
Change OFF of Bit [3: Remote controller Sub/
Master] of switch S003 to ON.
[Operation]
1. The operation contents can be changed by Last-push-priority.
2. Use a timer on either Master remote controller or Sub remote controller.
Terminal block for
remote controller cables
Remote controller
cables (Procured locally)
Indoor unit
Outdoor u
nit
Remote controller
switch (Sub)
Remote controller
switch (Master)
Sold separately
2
1
3
2
1
3
B
A
Sold separately
Master remote
controller
Remote controller
address connector
Rear side of remote
controller P.C. board
Sub
remote controller
Sensor
cover
Adjust
corner cap
1
2
3
4
ON
Sensor P.C. board
S003
Bit 1 : OFF to ON