beautypg.com

5. simple check method for main parts, 5-1. indoor unit – Toshiba RAV-SM560BT-E User Manual

Page 132

background image

132

14-5. Simple Check Method for Main Parts

14-5-1. Indoor unit

No.

1

Part name

Temperature sensor (Ta)
Heat exchanger sensor (Tc)
Heat exchanger sensor (Tcj)

Check procedure

Measure the resistance value with tester by removing the connector.
(Normal temperature)

Normal value

lMeasure the resistance value of each winding coil with tester.

lFor P.C. board side, proceed to [11 error] of

Troubleshooting procedure for each

check code

.

10 k

to 20 k

Refer to Characteristics table.

Measure the resistance value of each winding coil with tester.
(Under normal temperature 25

°

C)

Louver motor
MP35EA12

Position

Between 1 and 2
Between 1 and 3
Between 1 and 4
Between 1 and 5

Resistance value

130 ± 40

Indoor fan motor
(ICF-340-30-1)

Position

Between

ƒ

(Black) and



(Red)

Between

ƒ

(Black) and

„

(White)

Between

ƒ

(Black) and

…

(Yellow)

Between

ƒ

(Black) and

†

(Blue)

Resistance value

(M

)

27 to 47 k

140 to 280 k

(M

)

2

3

Red

Black

White

Yellow

Blue

6

5

4

3

1

6

5

4

3

1

6

5

4

3

1

6

5

4

3

2

1

Brown

Red

Orange

Yellow

Pink

Blue

6

5

4

3

2

1

6

5

4

3

2

1

Circuit