Automatic Increment/Decrement

^IREPV,2,050^G

This command causes Level A and all the following
passes to be repeated twice vertically, with a
spacing of 0.5 inches.

Level A

Printed data.

^IREPH,2,150^G

This command causes Level B and all other
Graphics Passes within this level to be printed
twice horizontally with a spacing of 1.5 inches.

^T003

Tabs the two columns of Level B data 0.3 inches
from the left margin.

Level B

Printed data.

^IREPV,3,020^G

this command causes Level C to print three times
vertically with a spacing of 0.2 inches.

^T005

Tabs the two columns of Level C data 0.5 inches
from the left margin.

Level C

Printed data.

Automatic Increment/Decrement

Data items within a repeat sequence can be increased or decreased in
predetermined amounts using the following increment or decrement syntax.

Command ^Yx+/-z^G

Arguments

^Y

Turns ON the Automatic Increment/Decrement
Mode.

x

The operand (the value you start with in any
arithmetic operation). This value can be up to
twelve characters long. Valid characters are 0 to 9,
the capital letters A to Z, and spaces.

+/-

Select either the + or the - sign to determine
whether the operand will be incremented or
decremented, respectively.

z

The operator (the amount that is incremented or
decremented at each step). This must be a numeric
value up to 12 digits long. If the operator exceeds
12 digits or if it contains non-numeric characters
(other than spaces), the operand remains
unchanged.

^G

Increment/Decrement Terminator