beautypg.com

Maintenance, Trouble indications, Temp indicator – Toshiba TLP-B2U User Manual

Page 54: 54 maintenance

background image

CONTENTS

54

Maintenance

If there is some problem inside the
projector, the indicators light up or flash.

Trouble indications

The power does not come on.

Malfunction of the unit.

• Unplug the power cord and call the dealer.

Note

Before attempting any maintenance, unplug the power cord.

TEMP indicator
LAMP indicator
ON indicator

ON

LAMP

TEMP

ON

LAMP

TEMP

(OFF)

or

Lit

(red)

ON

LAMP

TEMP

Lit

(red)

ON

LAMP

TEMP

Lit

(red)

Lit

(red)

Lit

(red)

ON

LAMP

TEMP

The lamp turns off or does not light up.

The lamp’s end, or malfunction of the unit.

• Lamp’s life length is over, replace the lamp with new one.

• Unplug the power cord and call the dealer.

The power turns off or does not come on.

The inside is too hot, or the projector has been working in
an area of high temperature.

• Place the projector correctly so the intake and exhaust

fans’ holes are not covered.

• Turn the projector off, and leave it for a while, and turn it

on again.

• Clean the air filter.

The power turns off or does not come on.

Trouble with the intake fan.

• Unplug the power cord and call the dealer.

The power turns off or does not come on.

Trouble with the exhaust fan.

• Unplug the power cord and call the dealer.

Lit

(red)

Flashing

(red)

ON

LAMP

TEMP

Lit

(red)

Flashing
(orange)