F936, F937, F938 – Toshiba H9 User Manual
Page 231: F939, F940
H9 ASD Installation and Operation Manual
223
Input Function Command 1
Program
⇒
My Function
⇒
My Function Unit 4
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
lists the available selections. Their use and selection
requirements are described in an example at
Direct Access Number — F936
Parameter Type — Selection List
Factory Default — 0 (NOP)
Input Function Target 2
Program
⇒
My Function
⇒
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 2
terminal.
This setting assigns the function of the programmable Input Function Target 2
terminal to any one of the user-selectable functions listed in
,
for more information on this parameter.
Direct Access Number — F937
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Command 2
Program
⇒
My Function
⇒
My Function Unit 4
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
lists the available selections. Their use and selection
requirements are described in an example at
Direct Access Number — F938
Parameter Type — Selection List
Factory Default — 0 (NOP)
Input Function Target 3
Program
⇒
My Function
⇒
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
,
for more information on this parameter.
Direct Access Number — F939
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Output Function Assigned
Program
⇒
My Function
⇒
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function
Assigned data location to one of the functions listed in the Input Setting field
of
.
Settings:
0 – 3099
See the My Function Instruction Manual (P/N 58692) and
for more
information on this parameter.
Direct Access Number — F940
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes