RAD Data comm AMC-101 User Manual
Page 23
AMC-101 Installation & Operation Manual
Chapter 1 - Introduction
Specifications
1-13
Table 1-2 Electrical Module Characteristics
Module Name
Protocols
Supported
Cable Type
Connector
Type
Range
Impedance
(Ohms)
UTP/155*
STS-3c
UTP Cat 5
Shielded RJ-45
100 m
100
STP/155*
STS-3c
STP Type 1
DB-9
100 m
150
UTP/100*
FDDI,
UTP Cat 5
Shielded RJ-45
100 m
100
CX/BNC/155**
STS-3c STM-1
Coax
BNC
12.7 dB*
75
CX/DIN/155**
STS-3c STM-1
Coax
DIN 47295 1.6/5.6 Coaxial
connector
12.7 dB*
75
* 50 m in transparent module
** Retimed only, 135 m is attainable when using RG-59 B/U cable (At 78 MHz, according to square root of
frequency law)
Table 1-3 Bridging Modules
Module Name
Protocols
Supported
Cable Type
Connector
Type
Range
Impedance
(Ohms)
10BT/B*
Ethernet
UTP Cat 5
Shielded RJ-45
100 m
100
100BT/B**
Fast Ethernet
UTP Cat 5
Shielded RJ-45
80 m
100
100BT/R***
Fast Ethernet
UTP Cat 5
Shielded RJ-45
80 m
100
* Remote Ethernet bridge module
** Remote Fast Ethernet bridge module
*** Media Converter for Fast Ethernet (Tx to Fx)