Installation
5.2.2 Cable Preparations
You need to connect the power supply (12 to 24 VDC) and the signal
output wires. Use only cable with outside diameter from 4 to 6 mm
(0.16 to 0.24 in), AWG 24.
The cable must include shielded wires. It should not be
used as a strain relief!
1. Cut about 40 mm (1.5 in) of the cable sheath (7) from the end
of the cable. Caution: Do not cut into the shield!
2. Cut the shield (5) so about 5 mm (0.2 in) remains exposed
from under the cable sheath (7). Separate the shield and
spread the strands out. Shorten the inside insulation until
you can separate the wires (6).
3. Strip 3 mm (0.15 in) of insulation from the wires (6).
Figure 5: Cable Preparation
4. Open the electronic box by removing the four Phillips head
screws and pulling off the lid. Unscrew the cap (1), and
remove the plastic compression fitting (2), the rubber washer
(3), which is inside the fitting, and the two metal washers (4).
16
MID