beautypg.com

Cable preparations, 2 cable preparations, Installation – RayTek 54301 User Manual

Page 24: 16 mid

background image

Installation

 

5.2.2 Cable Preparations 

You need to connect the power supply (12 to 24 VDC) and the signal 
output wires.  Use only cable with outside  diameter from 4 to 6 mm 
(0.16 to 0.24 in), AWG 24. 

The  cable  must  include  shielded  wires.  It  should  not  be 
used as a strain relief! 

1.  Cut about 40 mm (1.5 in) of the cable sheath (7) from the end 

of the cable. Caution: Do not cut into the shield! 

2.  Cut  the  shield  (5)  so  about  5  mm  (0.2  in)  remains  exposed 

from  under  the  cable  sheath  (7).  Separate  the  shield  and 
spread  the  strands  out.  Shorten  the  inside  insulation  until 
you can separate the wires (6). 

3.  Strip 3 mm (0.15 in) of insulation from the wires (6). 

 

Figure 5: Cable Preparation 

4.  Open  the  electronic  box  by  removing  the  four  Phillips  head 

screws  and  pulling  off  the  lid.  Unscrew  the  cap  (1),  and 
remove the plastic compression fitting (2), the rubber washer 
(3), which is inside the fitting, and the two metal washers (4). 

16 

MID